Year 2019 / Volume 30 / Number 1

Reviews

Effects of the Low-Dye tape on the foot. A narrative review

Rev. Esp. Pod. 2019; 30(1): 38-52 / DOI: 10.20986/revesppod.2019.1526/2018

Óscar Madruga Armada, Raúl Juan Molines Barroso, Ángel Manuel Orejana García


ABSTRACT

The Low-Dye tape is considered the gold standard among the tape techniques for the control of the fall of the longitudinal arch of the foot according to the literature. This tape technique has attracted the attention of numerous studies in recent years, in which its mechanical and clinical effects have been evaluated.
Kinetically, the collected clinical trials coincide in the generation of a decrease in plantar pressures in the medial region of the forefoot and its aument in the lateral midfoot region. Kinematically, the study of the internal longitudinal arch has focused the attention of a greater number of authors, due to the anatomical location of the Low-Dye tape. The main kinematic effect produced by the placement of the Low-Dye tape consists in a decrease in the fall of the internal longitudinal arch. Finally, at a clinical level, the improvement of pain in patients with plantar fasciitis is highlighted by the use of the Low-Dye tape.
In conclusion, the kinetic and kinematic effects observed would be related to a decrease in the net moment of pronation force that supports the foot as well as the net moment of dorsal flexion that support the joints of the internal column and could favor the establishment of the Windlass mechanism. By favoring the mechanism of Windlass, tensile stress that support various structures, such as the plantar fascia, decreases, improving pain related to this pathology according to the literature. Despite this, it is necessary to carry out more trials to evaluate the effects of this bandage.



RESUMEN

El vendaje Low-Dye se considera el gold estándar entre las técnicas de vendaje para el control de la caída del arco longitudinal del pie, según la literatura. Dicha técnica de vendaje ha recogido la atención de numerosos estudios en los últimos años, en los cuales se ha evaluado sus efectos mecánicos y clínicos.
Cinéticamente, los ensayos clínicos recogidos coinciden en que genera una disminución de las presiones plantares en la región medial del antepié y su aumento en la región lateral del mediopié. Cinemáticamente, el estudio del arco longitudinal interno ha centrado la atención de un mayor número de autores, debido a la localización anatómica del vendaje Low-Dye. El principal efecto cinemático producto de la colocación del vendaje Low-Dye consiste en una disminución en la caída del arco longitudinal interno. Finalmente, a nivel clínico destaca la mejoría del dolor en pacientes con fascitis plantar mediante el uso del vendaje Low-Dye.
En conclusión, los efectos cinéticos y cinemáticos observados guardarían relación con una disminución del momento de fuerza pronador neto que soporta el pie, así como el momento de flexión dorsal neto que soportan las articulaciones de la columna interna y podría favorecer la instauración del mecanismo de Windlass. Al favorecerse el mecanismo de Windlass, el estrés tensil que soportan diversas estructuras, como la fascia plantar, disminuye, mejorando así el dolor relacionado con esta patología según la bibliografía. Pese a ello es necesario la realización de más ensayos que evalúen los efectos de este vendaje.


Nuevo comentario

Security code:
CAPTCHA code image
Speak the codeChange the code
 

Comentarios

No comments in this article

Artículos relacionados

Ultrasound-detected ankle tenosynovitis is associated with foot function disorders: a cross-sectional study

Rev. Esp. Pod. 2024; 35(1): 11-16 / DOI: 10.20986/revesppod.2024.1692/2024

Morphology and function of the foot in patients with sciatica. A cross-sectional study

Rev. Esp. Pod. 2023; 34(2): 82-89 / DOI: 10.20986/revesppod.2023.1672/2023

Reflections on external tibial torsion and implications for biomechanics

Rev. Esp. Pod. 2022; 33(2): 128-133 / DOI: 10.20986/revesppod.2022.1652/2022

Update of new neuromuscular bandage techniques in podiatry

Rev. Esp. Pod. 2022; 33(1): 59-65 / DOI: 10.20986/revesppod.2022.1630/2022

Timing of foot stance in relation to the child’s age: a descriptive observational study

Rev. Esp. Pod. 2022; 33(1): 3-8 / DOI: 10.20986/revesppod.2022.1589/2020

Longitudinal arch load-sharing system of the foot

Rev Esp Podol. 2017;28(1):37-45

Talectomy. A case report

Rev. Esp. Pod. 2021; 32(2): 140-145 / DOI: 10.20986/revesppod.2021.1616/2021

Biomechanical study test in children and adolescents: a systematic review

Rev. Esp. Pod. 2021; 32(2): 132-139 / DOI: 10.20986/revesppod.2021.1611/2021

Kinematic analysis of ankle and midfoot joints in children with osteogenesis imperfecta

Rev. Esp. Pod. 2021; 32(2): 99-105 / DOI: 10.20986/revesppod.2021.1603/2021

Effectiveness of conservative treatments in patients with calcaneal apophysitis. Systematic review

Rev. Esp. Pod. 2021; 32(1): 42-48 / DOI: 10.20986/revesppod.2021.1593/2020

Mechanical determinants of external knee joint adductor moments during gait in healthy population

Rev. Esp. Pod. 2021; 32(1): 18-26 / DOI: 10.20986/revesppod.2021.1599/2021

Descriptive analysis of 3D foot motion using inertial sensors: comparison between lower extremities

Rev. Esp. Pod. 2021; 32(1): 13-17 / DOI: 10.20986/revesppod.2021.1594/2020

Relationship between dorsal ankle flexion and medial column flexibility

Rev. Esp. Pod. 2021; 32(1): 7-12 / DOI: 10.20986/revesppod.2021.1572/2020

Study of the response to aerobic resistance exercises based on the type of foot in the child population

Rev. Esp. Pod. 2020; 31(2): 71-75 / DOI: 10.20986/revesppod.2020.1560/2020

Dynamic instability of the pelvis and its relation to plantar pressures in runners

Rev. Esp. Pod. 2020; 31(2): 65-70 / DOI: 10.20986/revesppod.2020.1558/2020

How to give advise on footwear to running patients? From scientific evidence to clinical experience

Rev. Esp. Pod. 2020; 31(1): 46-54 / DOI: 10.20986/revesppod.2020.1571/2020

Effects of a stabilizer sock in balance in patients with different neurologic diseases

Rev. Esp. Pod. 2020; 31(1): 38-45 / DOI: 10.20986/revesppod.2020.1566/2020

Provision of orthopaedic footwear to patients in a hospital area: transversal study

Rev. Esp. Pod. 2019; 30(2): 81-86 / DOI: 10.20986/revesppod.2019.1547/2019

Effectiveness of conservative orthotic treatment in flexible pediatric flatfoot

Rev Esp Podol. 2018;29(1):2-12 / DOI: 10.20986/revesppod.2018.1507/2018

Instrucciones para citar

Madruga Armada Ó, Molines Barroso R, Orejana García Á. Effects of the Low-Dye tape on the foot. A narrative review. Rev Esp Pod 2019; 30(1): 38-52 / DOI: 1020986/revesppod20191526/2018


Descargar a un gestores de citas

Descargue la cita de este artículo haciendo clic en uno de los siguientes gestores de citas:

Métrica

Este artículo ha sido visitado 73385 veces.
Este artículo ha sido descargado 7 veces.

Estadísticas de Dimensions


Estadísticas de Plum Analytics

Ficha Técnica

Recibido: 05/10/2018

Aceptado: 03/02/2019

Prepublicado: 26/03/2019

Publicado: 28/06/2019

Tiempo de revisión del artículo: 116 días

Tiempo de prepublicación: 172 días

Tiempo de edición del artículo: 266 días


Compartir

Este artículo aun no tiene valoraciones .
Reader rating:
Rate this article:
2024 Revista Española de Podología
ISSN: 0210-1238   e-ISSN: 2695-463X

      Indexada en: