Año 2012 / Volumen 23 / Número 6

Artículos Originales

Estudio clínico del tratamiento de las exóstosis digitales mediante la implantación de un gel biocompatible

Rev Esp Pod 2012;23:216-24

Enrique Giralt de Veciana (1), Elena de Planell Mas (2), Elvira Mª Bonilla Toyos (3), Virginia Novel Martí (4), Patricia Carvalho Lobato (5), Mª Cristina Manzanares Céspedes (6). (1) Profesor Titular. Departamento de Podología. Universidad de Barcelona. (2) Profesor Colaborador. Departamento de Podología. Universidad de Barcelona. (3) Profesor Máster Oicial Podología Quirúrgica. Departamento de Podología. Universidad de Barcelona. (4) Profesor Titular. Departamento de Podología. Universidad de Barcelona. (5) Profesor Asociado. Departamento de Patología y Terapia Experimental. Universidad de Barcelona. (6) Profesor Titular. Departamento de Patología y Terapia Experimental.


Resumen

Antecedentes. La exóstosis digital es una patología común que se presenta con frecuencia en las consultas de podología. A pesar del alto grado de incidencia es una entidad clínica muy poco estudiada. En la actualidad, los tratamientos propuestos para resolver esta patología son el tratamiento conservador mediante ortesis de silicona y el tratamiento quirúrgico consistente en la resección de la exostosis. Consideramos necesario otra alternativa de tratamiento como la infiltración de un gel de Poliacrilamida (PAAG) que presente mayores beneficios y menos inconvenientes a los pacientes que los tratamientos propuestos hasta el momento.

Material y Métodos. Estudio realizado durante los meses de octubre de 2006 y febrero de 2009, sobre 54 pacientes (2 varones y 52 mujeres) de edades comprendidas entre 43 y 85 años afectados de exostosis digital. Se procede a la infiltración de un gel biocompatible en la zona de la exostosis para aislar la misma y evitar presiones según técnica de infiltración descrita. Todos los pacientes firman el documento de consentimiento informado. Los datos fueron recogidos de forma objetiva y subjetivamente en cada uno de los pacientes. La posterior evaluación de los datos y su tratamiento estadístico se llevó a cabo de forma disociada y anónima. El análisis estadístico se realizó con el paquete estadístico SPSS-PC 17.0.

Resultados. El heloma interdigital en 4o espacio y 5o dedo se presentó en el 35,2% de los casos; el heloma en dorso del 5o dedo en el 29,6%; el heloma en dorso de dedo central en el 11,1% de los casos; heloma interdigital en 4o espacio y 4o dedo en el 9,3%; y el resto de lesiones primarias en un 14,9% del total de los casos. De cada uno de los casos se observó: tratamientos previos, cantidad de fármaco infiltrada, reacción al fármaco, controles y satisfacción del paciente al tratamiento. A un 57,4% de los pacientes no se les había realizado ningún tratamiento previo, mientras que a un 33,3% se le había realizado una ortesis de silicona. Analizando la cantidad de PAAG infiltrado en cada caso nos resultó una media de 0,542 cc con una desviación típica de 0,2237 cc. La cantidad mínima fue de 0,20 cc, hasta un máximo de 1,50 cc. La reacción observada al fármaco a las 24 y 48 horas de la infiltración fue prácticamente la misma que la del periodo inicial, observándose el habón en ambos tiempos de valoración. Se practicaron cuatro controles posinfiltración a la semana, al mes, a los tres meses y a los seis meses, en los que a seis meses pudimos concluir que en la mayoría de los casos – 45 de 54 - persistió el habón de PAAG del inicio. La satisfacción se valora a la semana, al mes, a los tres meses y a los seis meses siendo a los 6 meses el grado de satisfacción de los pacientes del 98%.

Conclusiones. El tratamiento del heloma provocado por exostosis digital mediante infiltración de gel de poliacrilamida según la técnica protocolizada en este estudio clínico es factible, reproductible y eficaz. Alcanzando el  producto un alto nivel de tolerancia y adaptación a las estructuras anatómicas y disminuyendo los efectos secundarios, lo que nos hace afirmar que es una técnica segura con la que hemos obtenido óptimos resultados en lo que se refiere a efectividad del tratamiento y disminución del dolor. Podemos concluir que la infiltración de gel de poliacrilamida se convierte una nueva opción de tratamiento en el caso de exostosis digitales.

Abstract

Precedents. Digital exostosis is a common pathology often seen in podiatry clinics. Despite the high rates of incidence, it is a rarely studied clinical entity. Currently proposed treatments are: conservative treatment with silicone orthosis, and surgical treatment based on the resection of exostosis. We consider that an alternative treatment is necessary. Polyacrylamide Gel (PAAG) injection would bring patients more benefits and less drawbacks than the available treatments.

Materials and Methods. The clinical study was conducted between October 2006 and February 2009, with 54 patients (2 male and 52 female) aged between 43 and 85 years, affected by digital exostosis. Injection of biocompatible gel is performed in the area of exostosis, to isolate it and avoid pressures according to the described injection technique. All patients signed the informed consent. Data was recorded objectively and subjectively for each of the patients. Subsequent evaluation and statistical treatment of data were carried out separately and anonymously. Statistical software SPSS-PC 17.0 was used for the statistical analysis of data.

Results. Interdigital heloma located in the fourth interdigital space and in the fifth toe appeared in 35,2% of cases; heloma on the back of middle toe in 11,1% of cases; interdigital heloma in the fourth interdigital space and in the fourth toe in 9,3% of cases, and the remaining primary lesions in 14,9% of the total cases. For each case, several items were observed: previous treatments, quantity of injected gel, reaction to injection, controls, and patient’s satisfaction after treatment. 57,4% of patients had not undergone any previous treatment, whereas 33,3% of patients had already used a silicone orthosis. After analysing the quantity of injected PAAG in each case, it was obtained an average of 0,542 cc with a typical deviation of 0,2237cc. Minimum injected quantity was 0,20 cc, while the maximum quantity injected was 1,50 cc. Reaction was observed 24 / 48 hours after injection, and it was almost the same as in the initial period. Four post-injection controls were carried out one week after injection, one month after, three months after, and six months after injection. After six months, we could conclude that in the majority of cases -45 out of 54- the initial PAAG lump at injection site persisted. Patient satisfaction was evaluated 1 week after injection, one month after injection, three months after, and six months after. After 6 months, the rating of patient satisfaction was 98%.

Conclusions. The treatment of heloma caused by digital exostosis by injection of polyacrylamide gel, using a technique established in the protocol of this study, is considered feasible, to be reproduced, and effective. The product has achieved high rates of tolerance and adaptation to the anatomic structures, diminishing side effects, proving it is a safe method to obtain top results related to effectiveness of treatment and pain lessening. We can conclude that polyacrylamide gel injection has become a new option for the treatment of digital exostoses.


Nuevo comentario

Código de seguridad:
CAPTCHA code image
Speak the codeChange the code
 

Comentarios

No hay comentarios para este artículo.

Artículos relacionados

Instrucciones para citar

Enrique Giralt de Veciana (1), Elena de Planell Mas (2), Elvira Mª Bonilla Toyos (3), Virginia Novel Martí (4), Patricia Carvalho Lobato (5), Mª Cristina Manzanares Céspedes (6). (1) Profesor Titular. Departamento de Podología. Universidad de Barcelona. (2) Profesor Colaborador. Departamento de Podología. Universidad de Barcelona. (3) Profesor Máster Oicial Podología Quirúrgica. Departamento de Podología. Universidad de Barcelona. (4) Profesor Titular. Departamento de Podología. Universidad de Barcelona. (5) Profesor Asociado. Departamento de Patología y Terapia Experimental. Universidad de Barcelona. (6) Profesor Titular. Departamento de Patología y Terapia Experimental.. Estudio clínico del tratamiento de las exóstosis digitales mediante la implantación de un gel biocompatible. Rev Esp Pod 2012;23:216-24


Descargar a un gestores de citas

Descargue la cita de este artículo haciendo clic en uno de los siguientes gestores de citas:

Métrica

Este artículo ha sido visitado 44303 veces.
Este artículo ha sido descargado 20 veces.

Compartir

Este artículo aun no tiene valoraciones .
Valoración del lector:
Valora este artículo:
2024 Revista Española de Podología
ISSN: 0210-1238   e-ISSN: 2695-463X

      Indexada en: